Output Power | 100 W |
Sensor Type | Motion Sensor PIR |
Detection Angle | 360 ° |
Adjustable? | Yes |
Ignition Time | 10-420 s |
IP Protection Grade | IP65 |
Use | Indoor / Outdoor |
Sensing Distance | 19,69 ft |
Installment | Surface / Flush Mounted |
Frequency | 50/60 Hz |
Casing Color | White |
Mounting Height | 86,61-157,48 ft |
Diameter | 4 in |
Height | 0.7 in |
Weight | 4,37 oz |
The product adopts a good sensitivity detector, integrated circuit. SMT. It gathers automatism, convenience, safety, saving-energy, and practicality functions. The wide detection field is consisting of detectors. It works by receiving human motion infrared rays. When one enters the detection field, it can start the load at once and identify automatically day and night; its installation is very convenient and its use is very wide. It has functions of power indication and detection indication.
Highlights:
Can identify day and night: You can just adjust work ambient light, it can work in the daytime and at night when it is adjusted on the “+ (sun)” position (max). It can work in ambient light with less than 10LUX when it is adjusted on the “- (moon)” position (min).
Time-Delay is added continually: The lighting time is automatically overwritten. If someone is active in the detection area when the light is on, the lighting time will be retimed after each signal detection and the lighting time will be automatically extended.
Time–Delay is adjustable: It can be set according to the customer’s desire. The minimum time is 10sec ± 3sec. The maximum is 7min ± 3min.
Recommendations:
What if the load doesn’t work?
- Check the power if the connection-wiring of power and load is correct.
- Please check if the load is good.
- Please check if the working light sets correspond to the ambient light.
What if the sensitivity is poor?
- Please check if in front of the detection window there are any hinders that affect receiving the signals.
- Please check if the ambient temperature is too high.
- Please check if the source of the signal is in the detection fields.
- Please check the installation height.
When does the sensor won’t shut the load automatically?
- If there are continual signals in the detection fields.
- If the time delay is set to the longest.
- If the power doesn’t correspond to the instruction.
- If there is a high air temperature change near the sensor, like an air conditioner or central heating, etc.
Notes:
- Please refer to the installation sheet.
- When testing in daylight, please turn the LUX knob to the “+” (SUN) position, otherwise, the sensor lamp could not work.
- Electricians or experienced customers can install it.
- The unrest objects can’t be regarded as the installation basis-face.
- In front of the detection window, there shouldn’t be hinder or unrest objects affecting detection.